Order & Support:

CATEGORY

Order & Support:
01799797969

Salinity Calibration Solution 35.00 PPT 25 Pcs/Box

  • Salinity Calibration Solution 35PPT
  • Pack Size: 25 Sacket 20ml
  • Model: HI70024P
  • Brand: Hanna
  • Made in Romania

5,500৳ 

The Hanna Salinity Calibration Solution is a premium quality 35.00 ppt marine salinity solution standardized with a conductivity meter that has been calibrated with potassium chloride NIST 2202 SRM (Standard Reference Material) in de-ionized water for analytical use by ISO 3696/BS3978. The pack contains 25 Calibration Fluid Sachets.

Hanna Salinity Calibration Solution 35PPT 25 Pack (HI70024P)

Salinity calibration solutions are used to calibrate instruments that measure salinity in various solutions, such as water or other liquid samples. These calibration solutions typically contain a known concentration of salts to ensure the accuracy of salinity measurements. Calibration is crucial for maintaining the precision and reliability of salinity meters or sensors.
  • Reference Standard: Calibration solutions serve as reference standards with a known salinity concentration. Common units for salinity measurement include parts per thousand (ppt), practical salinity units (PSU), or specific gravity.
  • Preparation: Calibration solutions are prepared to closely match the salinity levels encountered in the actual samples being measured. This allows instruments to be calibrated across the expected range of salinity values.
  • Types of Salts: The composition of calibration solutions can vary, but they often contain a mix of salts such as sodium chloride (NaCl) and potassium chloride (KCl). The exact formulation depends on the specifications of the instrument and the desired salinity range.
  • Traceability: The calibration solution used must be traceable to a recognized standard, ensuring the accuracy and reliability of the calibration process.
  • Calibration Procedure: The calibration procedure involves adjusting the salinity meter or sensor readings based on the known salinity concentration of the calibration solution. This helps correct any systematic errors or drift in the instrument’s measurements.
  • Regular Calibration: Regular calibration is recommended to maintain the accuracy of salinity measurements over time. Environmental conditions, instrument aging, and other factors can affect the performance of salinity meters.

About Labzo Bangladesh

Labzo Bangladesh is a trusted seller, supplier, and stockist of high-quality Chinese-branded and non-branded laboratory equipment, scientific instruments, chemicals, reagents, microscopes, telescopes, medical devices, and more across Bangladesh.

We are committed to providing genuine products through both our online platform and direct sales, ensuring reliability, authenticity, and consistent quality for laboratories, educational institutions, research centers, and industrial users.

With a focus on affordable pricing, nationwide delivery, and professional after-sales support, Labzo Bangladesh is your go-to partner for all scientific and laboratory needs.

Our social media link: https://www.facebook.com/labzobangladesh

Delivery within 1-3 working days in Dhaka City and 3-5 working days anywhere in Bangladesh.

Labzo Bangladesh Website Disclaimer & Product Notice

Welcome to Labzo Bangladesh! Please read carefully before browsing or placing orders:

  1. Product Display & Variation

This website serves as a digital catalog or brochure to represent our company online.

Product images may slightly differ from physical products due to lighting, photography, or your device display settings.

To maintain product quality and prevent counterfeiting, actual products may vary from images shown.

  1. Pricing & Availability

Prices displayed are subject to market fluctuations and do not include VAT or AIT.

Products shown are not ready-stock items, but we can deliver within:

1–3 days in Dhaka City

3–5 days across Bangladesh

Liquid products cannot be delivered outside Dhaka City. Please do not place orders for liquid items from outside Dhaka.

  1. Special Caution

None of our chemicals or reagents are suitable for human consumption or food use.

These products are strictly for research, laboratory, and analytical purposes only.

  1. Office Pickup Notice

For direct pickup from our office, please inform us at least 3 hours in advance by phone.

Without prior notice, immediate pickup may not be possible.

  1. Copyright & Fair Use

This website may use some copyrighted materials under the “Fair Use” policy for purposes such as comment, news reporting, teaching, scholarship, research, and analysis.

Use for non-profit, educational, training, experimental, or personal purposes is considered fair use.

If you believe any content, image, video, or text infringes your copyright, please email us at kaziabdullah084@gmail.com.

All such content will be promptly removed.

Related Products

Hanna HI7031L 1413 µS/cm Conductivity Standard, 500mL
In Stock

3,200৳ 

Dissolved Oxygen Probe Electrolyte Solution HI7041S, 30ml
In Stock

3,000৳ 

pH Indicator Solution 500ml Qualikems
In Stock

1,100৳ 

Adwa TDS Standard Solution 1382 – 230ml AD7032
In Stock

3,850৳ 

Adwa TDS Standard Solution 1382 – 20ml AD70032P
In Stock

400৳ 

Adwa EC Standard Solution 1413 – 230ml AD7031
In Stock

3,850৳ 

Adwa AD70031P EC Standard Solution 1413 – 20 ml
In Stock

400৳ 

Hanna 3.5M KCl Electrolyte Solution 30ml for Double Junction Electrodes
In Stock

2,700৳ 

DO Meter Calibration Solution OXEL-03 Lutron
In Stock

3,500৳ 

Buffer Solution pH 4.01 Hanna 1000 ml Bottle
In Stock

3,000৳